Storage area network
A storage area network or storage network is a computer network which provides access to consolidated, block-level data storage. SANs are primarily used to access storage devices, such as disk arrays and tape libraries from servers so that the devices appear to the operating system as direct-attached storage. A SAN typically is a dedicated network of storage devices not accessible through the local area network.
Although a SAN provides only block-level access, file systems built on top of SANs do provide file-level access and are known as shared-disk file systems.
Storage architectures
Storage area networks are sometimes referred to as network behind the servers and historically developed out of a centralized data storage model, but with its own data network. A SAN is, at its simplest, a dedicated network for data storage. In addition to storing data, SANs allow for the automatic backup of data, and the monitoring of the storage as well as the backup process. A SAN is a combination of hardware and software. It grew out of data-centric mainframe architectures, where clients in a network can connect to several servers that store different types of data. To scale storage capacities as the volumes of data grew, direct-attached storage was developed, where disk arrays or just a bunch of disks were attached to servers. In this architecture, storage devices can be added to increase storage capacity. However, the server through which the storage devices are accessed is a single point of failure, and a large part of the LAN network bandwidth is used for accessing, storing and backing up data. To solve the single point of failure issue, a direct-attached shared storage architecture was implemented, where several servers could access the same storage device.DAS was the first network storage system and is still widely used where data storage requirements are not very high. Out of it developed the network-attached storage architecture, where one or more dedicated file server or storage devices are made available in a LAN. Therefore, the transfer of data, particularly for backup, still takes place over the existing LAN. If more than a terabyte of data was stored at any one time, LAN bandwidth became a bottleneck. Therefore, SANs were developed, where a dedicated storage network was attached to the LAN, and terabytes of data are transferred over a dedicated high speed and bandwidth network. Within the SAN, storage devices are interconnected. Transfer of data between storage devices, such as for backup, happens behind the servers and is meant to be transparent. In a NAS architecture data is transferred using the TCP and IP protocols over Ethernet. Distinct protocols were developed for SANs, such as Fibre Channel, iSCSI, Infiniband. Therefore, SANs often have their own network and storage devices, which have to be bought, installed, and configured. This makes SANs inherently more expensive than NAS architectures.
Components
SANs have their own networking devices, such as SAN switches. To access the SAN, so-called SAN servers are used, which in turn connect to SAN interfaces. Within the SAN a range of data storage devices may be interconnected, such as SAN capable disk arrays, JBODS and tape libraries.Host layer
Servers that allow access to the SAN and its storage devices are said to form the host layer of the SAN. Such servers have host bus adapters, which are cards that attach to slots on the server main board and run with a corresponding firmware and driver. Through the host bus adapters the operating system of the server can communicate with the storage devices in the SAN. A cable connects to the host bus adapter card through the gigabit interface converter. These interface converters are also attached to switches and storage devices within the SAN, and they convert digital bits into light impulses that can then be transmitted over the Fiber Channel cables. Conversely, the GBIC converts incoming light impulses back into digital bits. The predecessor of the GBIC was called gigabit link module. This is applicable for Fiber Channel deployments only.Fabric layer
The fabric layer consists of SAN networking devices that include SAN switches, routers, protocol bridges, gateway devices, and cables. SAN network devices move data within the SAN, or between an initiator, such as an HBA port of a server, and a target, such as the port of a storage device. SAN networks are usually built with redundancy, so SAN switches are connected with redundant links. SAN switches connect the servers with the storage devices and are typically non-blocking, thus transmitting data across all attached wires at the same time. When SANs were first built, hubs were the only devices that were Fibre Channel capable, but Fibre Channel switches were developed and hubs are now rarely found in SANs. Switches have the advantage over hubs that they allow all attached devices to communicate simultaneously, as a switch provides a dedicated link to connect all its ports with one another. SAN switches are for redundancy purposes set up in a meshed topology. A single SAN switch can have as few as 8 ports, up to 32 ports with modular extensions. So called director class switches can have as many as 128 ports. When SANs were first built Fibre Channel had to be implemented over copper cables, these days multimode optical fibre cables are used in SANs. In switched SANs the Fibre Channel switched fabric protocol FC-SW-6 is used, where every device in the SAN has a hardcoded World Wide Name address in the host bus adapter. If a device is connected to the SAN its WWN is registered in the SAN switch name server. In place of a WWN, or worldwide port name, SAN Fibre Channel storage device vendors may also hardcode a worldwide node name. The ports of storage devices often have an WWN starting with 5, while the bus adapters of servers start with 10 or 21.Storage layer
On top of the Fibre Channel-Switched Protocol is often the serialized Small Computer Systems Interface protocol, implemented in servers and SAN storage devices. It allows software applications to communicate, or encode data, for storage devices. The internet Small Computer Systems Interface over Ethernet and the Infiniband protocols may also be found implemented in SANs, but are often bridged into the Fibre Channel SAN. However, Infiniband and iSCSI storage devices, in particular, disk arrays, are available.The various storage devices in a SAN are said to form the storage layer. It can include a variety of hard disk and magnetic tape devices that store data. In SANs disk arrays are joined through a RAID, which makes a lot of hard disks look and perform like one big storage device. Every storage device, or even partition on that storage device, has a logical unit number assigned to it. This is a unique number within the SAN and every node in the SAN, be it a server or another storage device, can access the storage through the LUN. The LUNs allow for the storage capacity of a SAN to be segmented and for the implementation of access controls. A particular server, or a group of servers, may, for example, be only given access to a particular part of the SAN storage layer, in the form of LUNs. When a storage device receives a request to read or write data, it will check its access list to establish whether the node, identified by its LUN, is allowed to access the storage area, also identified by a LUN. LUN masking is a technique whereby the host bus adapter and the SAN software of a server restrict the LUNs for which commands are accepted. In doing so LUNs that should in any case not be accessed by the server are masked. Another method to restrict server access to particular SAN storage devices is fabric-based access control, or zoning, which has to be implemented on the SAN networking devices and the servers. Thereby server access is restricted to storage devices that are in a particular SAN zone.
Network protocols
Most storage networks use the SCSI protocol for communication between servers and disk drive devices. A mapping layer to other protocols is used to form a network:- ATA over Ethernet, mapping of ATA over Ethernet
- Fibre Channel Protocol, the most prominent one, is a mapping of SCSI over Fibre Channel
- Fibre Channel over Ethernet
- ESCON over Fibre Channel, used by mainframe computers
- HyperSCSI, mapping of SCSI over Ethernet
- iFCP or SANoIP mapping of FCP over IP
- iSCSI, mapping of SCSI over TCP/IP
- iSCSI Extensions for RDMA, mapping of iSCSI over InfiniBand
- Network block device, mapping device node requests on UNIX-like systems over stream sockets like TCP/IP
- SCSI RDMA Protocol, another SCSI implementation for RDMA transports
Examples of stacked protocols using SCSI:
Software
A SAN is primarily defined as a special purpose network, the Storage Networking Industry Association defines a SAN as "a network whose primary purpose is the transfer of data between computer systems and storage elements". But a SAN does not just consist of a communication infrastructure, it also has a software management layer. This software organizes the servers, storage devices, and the network so that data can be transferred and stored. Because a SAN is not a direct attached storage, the storage devices in the SAN are not owned and managed by a server. Potentially the data storage capacity that can be accessed by a single server through a SAN is infinite, and this storage capacity may also be accessible by other servers. Moreover, SAN software must ensure that data is directly moved between storage devices within the SAN, with minimal server intervention.SAN management software is installed on one or more servers and management clients on the storage devices. Two approaches have developed to SAN management software: in-band management means that management data between server and storage devices is transmitted on the same network as the storage data. While out-of-band management means that management data is transmitted over dedicated links. SAN management software will collect management data from all storage devices in the storage layer, including info on read and write failure, storage capacity bottlenecks and failure of storage devices. SAN management software may integrate with the Simple Network Management Protocol.
In 1999 an open standard was introduced for managing storage devices and provide interoperability, the Common Information Model. The web-based version of CIM is called Web-Based Enterprise Management and defines SAN storage device objects and process transactions. Use of these protocols involves a CIM object manager, to manage objects and interactions, and allows for the central management of SAN storage devices. Basic device management for SANs can also be achieved through the Storage Management Interface Specification, were CIM objects and processes are registered in a directory. Software applications and subsystems can then draw on this directory. Management software applications are also available to configure SAN storage devices, allowing, for example, the configuration of zones and logical unit numbers.
Ultimately SAN networking and storage devices are available from many vendors. Every SAN vendor has its own management and configuration software. Common management in SANs that include devices from different vendors is only possible if vendors make the application programming interface for their devices available to other vendors. In such cases, upper-level SAN management software can manage the SAN devices from other vendors.
Filesystems support
In a SAN data is transferred, stored and accessed on a block level. As such a SAN does not provide data file abstraction, only block-level storage and operations. But file systems have been developed to work with SAN software to provide file-level access. These are known as shared-disk file system.Server operating systems maintain their own file systems on their own dedicated, non-shared LUNs, as though they were local to themselves. If multiple systems were simply to attempt to share a LUN, these would interfere with each other and quickly corrupt the data. Any planned sharing of data on different computers within a LUN requires software, such as SAN file systems or clustered computing.
In media and entertainment
systems require very high data transfer rates and very low latency. SANs in media and entertainment are often referred to as serverless due to the nature of the configuration which places the video workflow desktop clients directly on the SAN rather than attaching to servers. Control of data flow is managed by a distributed file system such as StorNext by Quantum. Per-node bandwidth usage control, sometimes referred to as quality of service, is especially important in video editing as it ensures fair and prioritized bandwidth usage across the network.Quality of service
SAN Storage QoS enables the desired storage performance to be calculated and maintained for network customers accessing the device.Some factors that affect SAN QoS are:
- Bandwidth The rate of data throughput available on the system.
- Latency The time delay for a read/write operation to execute.
- Queue depth The number of outstanding operations waiting to execute to the underlying disks.
Using SAN storage QoS is in contrast to using disk over-provisioning in a SAN environment. Over-provisioning can be used to provide additional capacity to compensate for peak network traffic loads. However, where network loads are not predictable, over-provisioning can eventually cause all bandwidth to be fully consumed and latency to increase significantly resulting in SAN performance degradation.