Transmission electron cryomicroscopy


Transmission electron cryomicroscopy, commonly known as cryo-EM, is a form of cryogenic electron microscopy, more specifically a type of transmission electron microscopy where the sample is studied at cryogenic temperatures. Cryo-EM is gaining popularity in structural biology.
The utility of transmission electron cryomicroscopy stems from the fact that it allows the observation of specimens that have not been stained or fixed in any way, showing them in their native environment. This is in contrast to X-ray crystallography, which requires crystallizing the specimen, which can be difficult, and placing them in non-physiological environments, which can occasionally lead to functionally irrelevant conformational changes.
Recent advances in detector technology and software algorithms have allowed for the determination of macromolecular structures at near-atomic resolution by cryo-EM. These include viruses, ribosomes, mitochondria, ion channels, and enzyme complexes. As of 2018, cryo-EM can be applied to structures as small as hemoglobin and with resolutions up to 1.8 Å. Cryo-EM structures currently represent just over 2.5% of structures deposited in the Protein Data Bank, although this number is rapidly increasing as more and more cryo-EM structures are published each year. An application of cryo-EM is cryo-electron tomography, where a 3D reconstruction of the sample is created from tilted 2D images.

Development

The original rationale for CryoTEM was as a means to fight radiation damage for biological specimens. The amount of radiation required to collect an image of a specimen in the electron microscope is high enough to be a potential source of specimen damage for delicate structures. In addition, the high vacuum required on the column of an electron microscope makes the environment for the sample quite harsh.
The problem of the vacuum was partially solved by the introduction of negative stains but even with negative stains biological samples are prone to structural collapse upon dehydration of the specimen. Embedding the samples in ice below the sublimation temperature was a possibility that was contemplated early on, but water tends to arrange into a crystalline lattice of lower density upon freezing and this can destroy the structure of anything that is embedded in it.
In the early 1980s, several groups studying solid state physics were attempting to produce vitreous ice by different means, such as high pressure freezing or flash freezing. In a seminal paper in 1984, the group led by Jacques Dubochet at the European Molecular Biology Laboratory showed images of adenovirus embedded in a vitrified layer of water. This paper is generally considered to mark the origin of Cryo-EM, and the technique has been developed to the point of becoming routine at numerous laboratories throughout the world.
The energy of the electrons used for imaging is high enough that covalent bonds can be broken. When imaging specimens are vulnerable to radiation damage, it is necessary to limit the electron exposure used to acquire the image. These low exposures require that the images of thousands or even millions of identical frozen molecules be selected, aligned, and averaged to obtain high-resolution maps, using specialized software. A significant improvement in structural features was achieved in 2012 by the introduction of direct electron detectors and better computational algorithms.
In 2015, Bridget Carragher and colleagues at the Scripps National Resource for Automated Molecular Microscopy used techniques she and Clint Potter developed to determine the first cryo-EM structure with a resolution finer than 3 Å, thereby elevating CryoTEM as a tool comparable to and potentially superior to traditional x-ray crystallography techniques. Since then, higher resolutions have been achieved, including a 2.2 Å structure of bacterial enzyme β-galactosidase in 2015 and a 1.8 Å structure of glutamate dehydrogenase in 2016. Cryo-EM has also been used to determine the structure of various viruses, including the Zika virus, and has been applied to large complexes such as the spliceosome. In 2017, the Nobel Prize in Chemistry was awarded jointly to Jacques Dubochet, Joachim Frank and Richard Henderson, "for developing cryo-electron microscopy for the high-resolution structure determination of biomolecules in solution".

Biological specimens

Thin film

The biological material is spread on an electron microscopy grid and is preserved in a frozen-hydrated state by rapid freezing, usually in liquid ethane near liquid nitrogen temperature. By maintaining specimens at liquid nitrogen temperature or colder, they can be introduced into the high-vacuum of the electron microscope column. Most biological specimens are extremely radiosensitive, so they must be imaged with low-dose techniques.
Consequently, the images are extremely noisy. For some biological systems it is possible to average images to increase the signal-to-noise ratio and retrieve high-resolution information about the specimen using the technique known as single particle analysis. This approach in general requires that the things being averaged are identical, although some limited conformational heterogeneity can now be studied. Three-dimensional reconstructions from CryoTEM images of protein complexes and viruses have been solved to sub-nanometer or near-atomic resolution, allowing new insights into the structure and biology of these large assemblies.
Analysis of ordered arrays of protein, such as 2-D crystals of transmembrane proteins or helical arrays of proteins, also allows a kind of averaging which can provide high-resolution information about the specimen. This technique is called electron crystallography.

Vitreous sections

The thin film method is limited to thin specimens because the electrons cannot cross thicker samples without multiple scattering events. Thicker specimens can be vitrified by plunge freezing in ethane or more commonly by high pressure freezing. They can then be cut in thin sections with a diamond knife in a cryoultramicrotome at temperatures lower than -135 °C. The sections are collected on an electron microscope grid and are imaged in the same manner as specimen vitrified in thin film. This technique is called transmission electron cryomicroscopy of vitreous sections or transmission electron cryomicroscopy of frozen-hydrated sections.

Material specimens

In addition to allowing vitrified biological samples to be imaged, CryoTEM can also be used to image material specimens that are too volatile in vacuum to image using standard, room temperature electron microscopy. For example, vitrified sections of liquid-solid interfaces can be extracted for analysis by CryoTEM, and sulfur, which is prone to sublimation in the vacuum of electron microscopes, can be stabilized and imaged in CryoTEM.

Techniques

A variety of techniques can be used in CryoTEM. Popular techniques include:
  1. Electron crystallography
  2. # Analysis of two-dimensional crystals
  3. # Analysis of helical filaments or tubes
  4. #Microcrystal Electron Diffraction
  5. Single particle analysis
  6. #Time-resolved CryoTEM
  7. Electron cryotomography