Temperature-responsive polymer


Temperature-responsive polymers or thermoresponsive polymers are polymers that exhibit a drastic and discontinuous change of their physical properties with temperature. The term is commonly used when the property concerned is solubility in a given solvent, but it may also be used when other properties are affected. Thermoresponsive polymers belong to the class of stimuli-responsive materials, in contrast to temperature-sensitive materials, which change their properties continuously with environmental conditions.
In a stricter sense, thermoresponsive polymers display a miscibility gap in their temperature-composition diagram. Depending on whether the miscibility gap is found at high or low temperatures, an upper or lower critical solution temperature exists, respectively.
Research mainly focuses on polymers that show thermoresponsivity in aqueous solution. Promising areas of application are tissue engineering, liquid chromatography, drug delivery and bioseparation. Only a few commercial applications exist, for example, cell culture plates coated with an LCST-polymer.; top: coil-to-globule transition in solution; bottom: attached to a surface

History

The theory of thermoresponsive polymer begins in the 1940s with work from Flory and Huggins who both independently produced similar theoretical expectations for polymer in solution with varying temperature.
The effects of external stimuli on particular polymers were investigated in the 1960s by Heskins and Guillet. They established 32 °C as the lower critical solution temperature for poly.

Coil-globule transition

Thermoresponsive polymer chains in solution adopt an expanded coil conformation. At the phase separation temperature they collapse to form compact globuli. This process can be observed directly by methods of static and dynamic light scattering. The drop in viscosity can be indirectly observed. When mechanisms which reduce surface tension are absent, the globules aggregate, subsequently causing turbidity and the formation of visible particles.

Phase diagrams of thermoresponsive polymers

The phase separation temperature is dependent on polymer concentration. Therefore, temperature-composition diagrams are used to display thermoresponsive behavior over a wide range of concentrations. Phases separate into a polymer-poor and a polymer-rich phase. In strictly binary mixtures the composition of the coexisting phases can be determined by drawing tie-lines. However, since polymers display a molar mass distribution this straightforward approach may be insufficient.
During the process of phase separation the polymer-rich phase can vitrify before equilibrium is reached. This depends on the glass transition temperature for each individual composition. It is convenient to add the glass transition curve to the phase diagram, although it is no real equilibrium. The intersection of the glass transition curve with the cloud point curve is called Berghmans point. In the case of UCST polymers, above the Berghmans point the phases separate into two liquid phases, below this point into a liquid polymer-poor phase and a vitrified polymer-rich phase. For LCST polymers the inverse behavior is observed.

Thermodynamics

Polymers dissolve in a solvent when the Gibbs energy of the system decreases, i.e., the change of Gibbs energy is negative. From the known Legendre transformation of the Gibbs–Helmholtz equation it follows that ΔG is determined by the enthalpy of mixing and entropy of mixing.
Without interactions between the compounds there would be no enthalpy of mixing and the entropy of mixing would be ideal. The ideal entropy of mixing of multiple pure compounds is always positive and ΔG would be negative for all compositions, causing complete miscibility. Therefore, the fact that miscibility gaps are observed can only be explained by interaction. In the case of polymer solutions, polymer-polymer, solvent-solvent and polymer-solvent interactions have to be taken into account. A model for the phenomenological description of polymer phase diagrams was developed by Flory and Huggins. The resulting equation for the change of Gibbs energy consists of a term for the entropy of mixing for polymers and an interaction parameter that describes the sum of all interactions.
where
A consequence of the Flory-Huggins theory is, for instance, that the UCST increases and shifts into the solvent-rich region when the molar mass of the polymer increases. Whether a polymer shows LCST and/or UCST behavior can be derived from the temperature-dependence of the interaction parameter. It has to be noted that the interaction parameter not only comprises enthalpic contributions but also the non-ideal entropy of mixing, which again consists of many individual contributions. For these reasons, classical Flory-Huggins theory cannot provide much insight into the molecular origin of miscibility gaps.

Applications

Bioseparation

Thermoresponsive polymers can be functionalized with moieties that bind to specific biomolecules. The polymer-biomolecule conjugate can be precipitated from solution by a small change of temperature. Isolation may be achieved by filtration or centrifugation.

Thermoresponsive surfaces

Tissue engineering

For some polymers it was demonstrated that thermoresponsive behavior can be transferred to surfaces. The surface is either coated with a polymer film or the polymer chains are bound covalently to the surface.
This provides a way to control the wetting properties of a surface by small temperature changes. The described behavior can be exploited in tissue engineering since the adhesion of cells is strongly dependent on the hydrophilicity/hydrophobicity. This way, it is possible to detach cells from a cell culture dish by only small changes in temperature, without the need to additionally use enzymes. Respective commercial products are already available.

Chromatography

Thermoresponsive polymers can be used as the stationary phase in liquid chromatography. Here, the polarity of the stationary phase can be varied by temperature changes, altering the power of separation without changing the column or solvent composition. Thermally related benefits of gas chromatography can now be applied to classes of compounds that are restricted to liquid chromatography due to their thermolability. In place of solvent gradient elution, thermoresponsive polymers allow the use of temperature gradients under purely aqueous isocratic conditions. The versatility of the system is controlled not only by changing temperature, but also by adding modifying moieties that allow for a choice of enhanced hydrophobic interaction, or by introducing the prospect of electrostatic interaction. These developments have already brought major improvements to the fields of hydrophobic interaction chromatography, size exclusion chromatography, ion exchange chromatography, and affinity chromatography separations, as well as pseudo-solid phase extractions.

Thermoresponsive gels

Covalently linked gels

Three-dimensional covalently linked polymer networks are insoluble in all solvents, they merely swell in good solvents. Thermoresponsive polymer gels show a discontineous change of the degree of swelling with temperature. At the volume phase transition temperature the degree of swelling changes drastically. Researchers try to exploit this behavior for temperature-induced drug delivery. In the swollen state, previously incorporated drugs are released easily by diffusion. More sophisticated "catch and release" techniques have been elaborated in combination with lithography and molecular imprinting.

Physical gels

In physical gels unlike covalently linked gels the polymers chains are not covalently linked together. That means that the gel could re-dissolve in a good solvent under some conditions. Thermoresponsive physical gels, also sometimes called thermoresponsive injectable gels have been used in Tissue Engineering. This involves mixing at room temperature the thermoresponsive polymer in solution with the cells and then inject the solution to the body. Due to the temperature increase the polymer creates a physical gel. Within this physical gel the cells are encapsulated. Tailoring the temperature that the polymer solution gels can be challenging because this depend by many factors like the polymer composition, architecture as well as the molar mass.

Characterization of thermoresponsive polymer solutions

Cloud point

Experimentally, the phase separation can be followed by turbidimetry. There is no universal approach for determining the cloud point suitable for all systems. It is often defined as the temperature at the onset of cloudiness, the temperature at the inflection point of the transmittance curve, or the temperature at a defined transmittance. The cloud point can be affected by many structural parameters of the polymer like the hydrophobic content, architecture and even the molar mass.

Hysteresis

The cloud points upon cooling and heating of a thermoresponsive polymer solution do not coincide because the process of equilibration takes time. The temperature interval between the cloud points upon cooling and heating is called hysteresis. The cloud points are dependent on the cooling and heating rates, and hysteresis decreases with lower rates. There are indications that hysteresis is influenced by the temperature, viscosity, glass transition temperature and the ability to form additional intra- and inter-molecular hydrogen bonds in the phase separated state.

Other properties

Another important property for potential applications is the extent of phase separation, represented by the difference in polymer content in the two phases after phase separation. For most applications, phase separation in pure polymer and pure solvent would be desirable although it is practically impossible. The extent of phase separation in a given temperature interval depends on the particular polymer-solvent phase diagram.
Example: From the phase diagram of polystyrene in the solvent cyclohexane it follows that at a total polymer concentration of 10%, cooling from 25 to 20 °C causes phase separation into a polymer-poor phase with 1% polymer and a polymer-rich phase with 30% polymer content.
Also desirable for many applications is a sharp phase transition, which is reflected by a sudden drop in transmittance. The sharpness of the phase transition is related to the extent of phase separation but additionally relies on whether all present polymer chains exhibit the same cloud point. This depends on the polymer endgroups, dispersity, or—in the case of copolymers—varying copolymer compositions.

Examples of thermoresponsive polymers

Thermoresponsivity in organic solvents

Due to the low entropy of mixing, miscibility gaps are often observed for polymer solutions. Many polymers are known that show UCST or LCST behavior in organic solvents. Examples for organic polymer solutions with UCST are polystyrene in cyclohexane, polyethylene in diphenylether or polymethylmethacrylate in acetonitrile. An LCST is observed for, e.g., polypropylene in n-hexane, polystyrene in butylacetate or polymethylmethacrylate in 2-propanone.

Thermoresponsivity in water

Polymer solutions that show thermoresponsivity in water are especially important since water as a solvent is cheap, safe and biologically relevant. Current research efforts focus on water-based applications like drug delivery systems, tissue engineering, bioseparation. Numerous polymers with LCST in water are known. The most studied polymer is poly. Further examples are poly hydroxypropylcellulose, poly and polyvinyl methyl ether.
Some industrially relevant polymers show LCST as well as UCST behavior whereas the UCST is found outside the 0-to-100 °C region and can only be observed under extreme experimental conditions. Examples are polyethylene oxide, polyvinylmethylether and polyhydroxyethylmethacrylate. There are also polymers that exhibit UCST behavior between 0 and 100 °C. However, there are large differences concerning the ionic strength at which UCST behavior is detected. Some zwitterionic polymers show UCST behavior in pure water and also in salt-containing water or even at higher salt concentration. By contrast, polyacrylic acid displays UCST behavior solely at high ionic strength. Examples for polymer that show UCST behavior in pure water as well as under physiological conditions are poly, ureido-functionalized polymers, copolymers from N-vinylimidazole and 1-vinyl-2-imidazole or copolymers from acrylamide and acrylonitrile. Polymers for which UCST relies on non-ionic interactions are very sensitive to ionic contamination. Small amounts of ionic groups may suppress phase separation in pure water.
The UCST is dependent on the molecular mass of the polymer. For the LCST this is not necessarily the case, as shown for poly.