Starling resistor


The Starling resistor was invented by English physiologist Ernest Starling and used in an isolated-heart preparation during work which would later lead to the "Frank–Starling law of the heart".
The device consisted of an elastic fluid-filled collapsible-tube mounted inside a chamber filled with air. The static pressure inside the chamber was used to control the degree of collapse of the tube, so providing a variable resistor. This resistance was used to simulate TPR, or total peripheral resistance.
Starling resistors have been used both as an instrument in the study of interesting physiological phenomena the “waterfall effect” wherein, subsequent to collapse, the flow through the tube becomes independent of the downstream pressure and 2) self-excited oscillations. Expiratory flow-limitation in the disease COPD is an example of the former behaviour and snoring an example of the latter.