MBAS assay


A methylene blue active substances assay, or MBAS assay, is a colorimetric analysis test method that uses methylene blue to detect the presence of anionic surfactants in a sample of water. An anionic surfactant detected by the color reaction is called a methylene blue active substance.
After first acidifying a water sample, one adds to it chloroform and a solution of methylene blue et al. Methylene blue is a cationic dye. The biphasic solution is then agitated to distribute these reagents throughout the aqueous and organic phases. If an anionic surfactant is present, then the cationic methylene blue and the anionic surfactant forms an ion pair, which is extracted into the organic phase. The color saturation of the chloroform increases with the concentration of anionic surfactants.
MBAS assay is an ASTM International standard technique for detecting anionic surfactants. These include carboxylates, phosphates, sulfates, and sulfonates. An MBAS assay alone does not, however, identify specific surfactants. ASTM withdrew the standard in 2011 pending a review and update of the method, which was last approved in 2003.
Standard Methods for the Examination of Water and Wastewater list the following methods used by certified laboratories testing wastewater in the United States: