Drinking water quality standards


Drinking water quality standards describes the quality parameters set for drinking water. Despite the truth that every human on this planet needs drinking water to survive and that water may contain many harmful constituents, there are no universally recognized and accepted international standards for drinking water. Even where standards do exist, and are applied, the permitted concentration of individual constituents may vary by as much as ten times from one set of standards to another.
Many developed countries specify standards to be applied in their own country. In Europe, this includes the European Drinking Water Directive and in the United States the United States Environmental Protection Agency establishes standards as required by the Safe Drinking Water Act. For countries without a legislative or administrative framework for such standards, the World Health Organization publishes guidelines on the standards that should be achieved. China adopted its own drinking water standard GB3838-2002 enacted by Ministry of Environmental Protection in 2002.
Where drinking water quality standards do exist, most are expressed as guidelines or targets rather than requirements, and very few water standards have any legal basis or, are subject to enforcement. Two exceptions are the European Drinking Water Directive and the Safe Drinking Water Act in the United States, which require legal compliance with specific standards.
In Europe, this includes a requirement for member states to enact appropriate local legislation to mandate the directive in each country. Routine inspection and, where required, enforcement is enacted by means of penalties imposed by the European Commission on non-compliant nations.
Countries with guideline values as their standards include Canada, which has guideline values for a relatively small suite of parameters, New Zealand, where there is a legislative basis, but water providers have to make "best endeavours" to comply with the standards, and Australia.

Range of standards

Although drinking water standards frequently are referred to as if they are simple lists of parametric values, standards documents also specify the sampling location, sampling methods, sampling frequency, analytical methods, and laboratory accreditation AQC. In addition, a number of standards documents also require calculation to determine whether a level exceeds the standard, such as taking an average. Some standards give complex, detailed requirements for the statistical treatment of results, temporal and seasonal variations, summation of related parameters, and mathematical treatment of apparently aberrant results.

Parametric values

A parametric value in this context is most commonly the concentration of a substance, e.g. 30 mg/l of Iron. It may also be a count such as 500 E. coli per litre or a statistical value such as the average concentration of copper is 2 mg/l. Many countries not only specify parametric values that may have health impacts but also specify parametric values for a range of constituents that by themselves are unlikely to have any impact on health. These include colour, turbidity, pH, and the organoleptic parameters.
It is possible and technically acceptable to refer to the same parameter in different ways that may appear to suggest a variation in the standard required. For example, nitrite may be measured as nitrite ion or expressed as N. A standard of "Nitrite as N" set at 1.4 mg/l equals a nitrite ion concentration of 4.6 mg/l. This is an apparent difference of nearly threefold.

Standards by country

Australia

Drinking water quality standards in Australia have been developed by the Australian Government National Health and Medical Research Council in the form of the Australian Drinking Water Guidelines. These guidelines provide contaminant limits as well as guidance on applying limits for the management of drinking water in Australian drinking water treatment and distribution.

European Union

The following parametric standards are included in the Drinking Water Directive and are expected to be enforced by appropriate legislation in every country in the European Union. Simple parametric values are reproduced here, but in many cases the original directive also provides caveats and notes about many of the values given.
In the United States, the federal legislation controlling drinking water quality is the Safe Drinking Water Act which is implemented by the U.S. Environmental Protection Agency, mainly through state or territorial health agencies.
EPA has set standards for over 90 contaminants organized into six groups: microorganisms, disinfectants, disinfection byproducts, inorganic chemicals, organic chemicals and radionuclides. States and territories must implement rules that are at least as stringent as EPA's to retain primary enforcement authority over drinking water. Many states also apply their own state-specific standards, which may be more rigorous or include additional parameters. Many countries look to the standards set by the EPA in the United States for appropriate scientific and public health guidance and may reference or adopt US standards.

World Health Organization Guidelines

The World Health Organization Guideline for Drinking-water Quality include the following recommended limits on naturally occurring constituents that may have direct adverse health impact:
Organic species:
The following table provides a comparison of a selection of parameters for concentrations listed by WHO, the European Union, EPA, and Ministry of Environmental Protection of China.
" indicates that no standard has been identified by editors of this article and ns indicates that no standard exists. μg/l -> Micro grams per litre or 0.001 ppm, mg/L -> 1 ppm or 1000 μg/l
* Action level; not a concentration standard. A public water system exceeding the action level must implement "treatment techniques" which are enforceable procedures.
** TT. The public water system must certify that the combination of dose and monomer level does not exceed: Acrylamide = 0.05% dosed at 1 mg/l ; Epichlorohydrin = 0.01% dosed at 20 mg/l.
ParameterTableWorld Health OrganizationEuropean UnionUnited StatesChinaCanada
1,2-dichloroethane"3.0 μg/l5 μg/l""
Acrylamide"0.10 μg/lTT**""
AluminiumAl0,2 mg/lno limit listed
AntimonySbns5.0 μg/l6.0 μg/l"6.00 μg/l
ArsenicAs10μg/l10 μg/l10μg/l50μg/l10.0 μg/l
BariumBa700μg/lns2 mg/L"1.00 mg/L
Benzene10μg/l1.0 μg/l5 μg/l""
Benzopyrene"0.010 μg/l0.2 μg/l0.0028 μg/l"
BerylliumBe"
BoronB2.4 mg/l1.0 mg/L""5.00 mg/L
Bromate"10 μg/l10 μg/l""
CadmiumCd3 μg/l5 μg/l5 μg/l5 μg/l5.00 μg/l
CalciumCa200 mg/L
ChromiumCr50μg/l50 μg/l0.1 mg/L50 μg/l 0.050 mg/L
CobaltCo"
CopperCu"2.0 mg/l1.3 mg/l*1 mg/l1.00 mg/L
Cyanide"50 μg/l0.2 mg/L50 μg/l"
Epichlorohydrin"0.10 μg/lTT**""
Fluoride1.5 mg/l1.5 mg/l4 mg/l1 mg/l"
GoldAuno limit listed
hardnessCaCO30–75 mg/L = soft
IronFe0,2 mg/l0.300 mg/L
LanthanumLano limit listed
LeadPb"10 μg/l15 μg/l*10 μg/l10.0 μg/l
MagnesiumMg50.0 mg/L
ManganeseMn0, 05 mg/l0.050 mg/L
MercuryHg6 μg/l1 μg/l2 μg/l0.05 μg/l1.00 μg/l
MolybdenumMono limit listed
NickelNi"20 μg/l""no limit listed
Nitrate50 mg/l50 mg/l10 mg/L 10 mg/L "
Nitrite"0.50 mg/l1 mg/L ""
Pesticides — Total"0.50 μg/l"""
Pesticides "0.10 μg/ l"""
pH6.5 to 8.5
PhosphorusPno limit listed
Polycyclic aromatic hydrocarbons l"0.10 μg/"""
PotassiumKno limit listed
ScandiumScno limit listed
SeleniumSe40 μg/l10 μg/l50 μg/l10 μg/l10.0 μg/l
SiliconSino limit listed
SilverAg0.050 mg/L
SodiumNa200 mg/L
StrontiumSrno limit listed
Tetrachloroethene and Trichloroethene40μg/l10 μg/l"""
TinSnno limit listed
TitaniumTino limit listed
TungstenWno limit listed
UraniumU0.10 mg/L
VanadiumVno limit listed
ZincZn5.00 mg/L
vinyl chloride0,50 μg/l
chlorides250 mg/l
electrical conductivity2500 μS cm-1 at 20 °C