Deriaz turbine


The Deriaz turbine, presented by engineer Paul Deriaz, was the first diagonal hydraulic pump-turbine to be designed. In contrast to most hydraulic machines, the flow in a Deriaz turbine does not follow a full axial nor radial direction but is a diagonal mixture of the two. Deriaz turbines, like Kaplan turbines, have also adjustable runner blades. Deriaz turbines are installed at the Sir Adam Beck Pump Generating Station at Niagara Falls.
The combined use of adjustable runner blades with moving guide vanes allows Deriaz pump-turbine to reach high performance under a large range of working conditions. This makes the Deriaz pump-turbine an extremely suitable turbomachine solution for high variable load. Recent investigation supported by experimental data and computational fluid dynamics simulations, shows clearly how a downsized prototype preserves versatility over a wide range of partial load for pumping and generating modes.