A cascade filling system is a high pressuregas cylinderstorage system which is used for the refilling of smaller compressed gas cylinders. In some applications, each of the large cylinders is filled by a compressor, otherwise they may be filled remotely and replaced when the pressure is too low for effective transfer. The cascade system allows small cylinders to be filled without a compressor. In addition, a cascade system is useful as a reservoir to allow a low-capacity compressor to meet the demand of filling several small cylinders in close succession, with longer intermediate periods during which the storage cylinders can be recharged.
Principle of operation
When gas contained in a cylinder at high pressure is allowed to flow to another cylinder containing gas at a lower pressure, the pressures will equalise to a value somewhere between the two initial pressures. The equilibrium pressure is affected by transfer rate as it will be influenced by temperature, but at constant temperature the equilibrium pressure is described by Dalton's law of partial pressures and Boyle's law for ideal gases. The formula for the equilibrium pressure is: An example could be a 100-litre cylinder pressurised to 200 bar filling a 10-litre cylinder which was unpressurised . If another 100 litre cylinder pressurised this time to 250 bar were then used to "top-up" the 10 litre cylinder, both of these cylinders would equalise to about 240 bar. However, if the higher pressure 100 litre cylinder were used first, the 10 litre cylinder would equalise to about 225 bar and the lower pressure 100 litre cylinder could not be used to top it up. In a cascade storage system, several large cylinders are used to bring a small cylinder up to a desired pressure, by always using the supply cylinder with the lowest usable pressure first, then the cylinder with the next lowest pressure, and so on. In practice the theoretical transfers can only be achieved if the gases are allowed to reach a temperature equilibrium before disconnection. This requires significant time, and a lower efficiency may be accepted to save time. Actual transfer can be calculated using the general gas equation of state if the temperature of the gas in the cylinder is accurately measured.
Uses
Breathing sets
A breathing set cylinder may be filled to its working pressure by decanting from larger cylinders. The storage cylinders are available in a variety of sizes, typically from 50 litre internal capacity to well over 100 litres. In the more general case a high pressure hose known as a filling whip is used to connect the filling panel or storage cylinder to the receiving cylinder. Cascade filling is often used for partial pressure blending of breathing gas mixtures for diving, to economize on the relatively expensive oxygen, for nitrox, and the even more expensive helium in trimix or heliox mixtures.
Cascade storage is used at compressed natural gas fueling stations. Typically three CNG tanks will be used, and a vehicle will first be fueled from one of them, which will result an incomplete fill, perhaps to 2000 PSI for a 3000 PSI tank. The second and third tanks will bring the vehicle's tank closer to 3000 PSI. The station normally has a compressor, which refills the station's tanks, using natural gas from a utility line. This prevents accidentally overfilling the tank, which could happen with a system using a single fueling tank at a higher pressure than the target pressure for the vehicle.
Hydrogen storage
In cascade storage systems for hydrogen storage, as for example at hydrogen stations, fuel dispenser A draws hydrogen from tank A, while dispenser B draws fuel from hydrogen tank B. If dispenser A is over-utilized, tank A will become depleted before tank B. At this point the dispenser A is switched to tank C. Tank C will then supply dispenser A and B and tank A until tank A is filled to the same pressure as tank B and the dispensers are disconnected, after which the control system will close the control valves to switch to its former state.
Arrangement of system
The storage cylinders may be used independently in sequence using a portable transfer whip with a pressure gauge and manual bleed valve, to transfill the receiving cylinder until the appropriate fill pressure has been reached, or the storage cylinders may be connected to a manifold system and a filling control panel with one or more filling whips. Ideally each storage cylinder has an independent connection to the filling panel with a contents pressure gauge and supply valve dedicated to that cylinder, and a filling gauge connected to the filling whip, so the operator can see at a glance the next higher storage cylinder pressure compared to the receiving cylinder pressure. The storage cylinders may be filled remotely and connected to the manifold by a flexible hose when in use, or may be permanently connected and refilled by a compressor through a dedicated filling system, which may be automated or manually controlled. An over-pressure safety valve is usually installed inline between the compressor and the storage units to protect the cylinders from overfilling, and each cylinder may also be protected by a rupture disc.